Application chiller systems     
   
(Download approx. 8,3MB)


PolyGard NH3 / Freone / CO2 - Sensors are used for the detection of leakages in cooling systems. Refrigerants are highly toxic and/or harmful to the environment. Accidental escape of the refrigerant is to avoid at any case. The MSR transmitters detect reliably any escape of the refrigerant gas and protect in combination with the MSR controllers and warning devices primarly persons, but also the plant. MSR Electronic products comply with current regulations.


MSR delivers sensors, controllers and accessories for cooling systems.

We have pointed out some features of the datasheets to give you a short overview.
 
 

MSR Sensors for NH3 Ammonia 

Sensor type Measuring  range   Signal output Type                         Datasheet 
Infrared 0-10000ppm
0-3.5 vol%
0(4)-20mA
0(2)-10V      RS485 
ADT-D3-1120 PDF
El-chem. 0-300ppm
0-1000ppm
0(4)-20mA
0(2)-10V      RS485
ADT-X3-1120/25 PDF 
El-chem.  0-300ppm
0-1000ppm  
4-20mA
2-10V 
MA-5-1120  PDF 
Semi-conductor 0-300ppm 0(4)-20mA
0(2)-10V      RS485
ADT-33-1120 PDF
Semi-conductor 30-300ppm 4-20mA
2-10V 
MA-3-1120 PDF 
Pellistor  0-100%LEL   0(4)-20mA
0(2)-10V      RS485 
ADT-23-3408  PDF 
Pellistor   0-100%LEL    4-20mA
2-10V  
MA-2-1120  PDF 
El-chem.         CESI / ATEX 0-200ppm
0-1000ppm
4-20mA      RS485 XT-21-1125 PDF
Pellistor          CESI / ATEX  0-100% UEG 4-20mA      RS485 XT-21-3408 PDF

 
  
 

The MSR Sensors for Freons  

Sensor type Measuring range   Signal output Type                     Datasheet 
 Infrared 0-2000ppm 0(4)-20mA 
0(2)10V    RS485 
ADT-D3-20xx PDF
 Semi-conductor 0-300ppm
0-2000ppm   
0(4)-20mA
0(2)10V    RS485 
ADT-43-20xx  PDF 
 Semi-conductor 0-300ppm
20-2000ppm   
4-20mA 
2-10V
MA-4-20xx PDF 

 
 
 

MSR Sensors für CO2 carbon dioxide  

Sensor type Measuring  range      Signal output Type                 Datasheet
Infrared 0-5vol% 0(4)-20mA
0(2)-10V      RS485 
ADT-D3-1164 PDF
Infrared           CESI / ATEX 0-2vol%
0-5vol%
4-20mA      RS485 XT-21-1160 PDF 

  
  
  

MSR Sensor for C2H4  Ethylene  
 

Sensor type Measuring
range     
Signal
output
Type                 Datasheet 
Pellistor 0-100%LEL 0(4)-20mA         0(2)-10V      RS485  ADT-23-3410 PDF
Pellistor
CESI / ATEX 
0-100%LEL 4-20mA 
RS485 
XT-21-3410P  PDF 
Infrared 
CESI / ATEX
0-100%LEL 4-20mA
RS485 
XTA1-3410I  PDF 
Semi-conductor  20-2000ppm  4-20mA   MA-3-2089  PDF 
Infrared   0-2000ppm  0(4)-20mA
0(2)-10V     
RS485  
ADT-D3-1189   PDF  
El-chem.   0-10ppm  0(4)-20mA
0(2)-10V
RS485 
ADT-53-1189   PDF 
Semi-conductor 20-2000ppm 0(4)-20mA
0(2)-10V
RS485
ADT-43-1189  PDF
El-chem.
CESI / ATEX  
0-200ppm   4-20mA
RS485   
XT-21-1190   PDF  


   
  

The MSR Single Point Controllers for refrigerants
 

Gas Analog inputs Digital outputs Type                    Datasheet 
 NH3 2 SPC-23-1120 PDF
 NH3 2 4 SPC-33-1120 PDF  
 NH3  SPC-D3-1120  PDF 
 Freon 2 SPC-43-20xx PDF
 Freon  2 4 SPC-D3-20xx PDF
 CO2 2 SPC-D3-1164 PDF
 C2H4 2 4 SPC-23-3410 PDF 
 C2H4  SPC-43-1189  PDF 
 C2H4 SPC-53-1189   PDF 
 C2H4 SPC-D3-1189   PDF 

  
  
 

MSR Controllers

Max. analog transmitters Max. digital transmitters Max. digital outputs Serie                Controller Controller module Expansion module 
2   4 MGC 03 PDF    
24   30 MGC 04 PDF  PDF  PDF
  98 30 DGC 05 PDF PDF  PDF 


You will find gateways to BMS in products or on request under: info@msr-electronic.de



MSR Accessories

Type            Datasheet
Warning sign with text PDF
Warning horn PDF 
Flashlight PDF
Combination warning horn/ flashlight PDF 






Please click on PDF to download the corresponding file.