PolyGard NH3 / Freone / CO2 - Sensors are used for the detection of leakages in cooling systems. Refrigerants are highly toxic and/or harmful to the environment. Accidental escape of the refrigerant is to avoid at any case. The MSR transmitters detect reliably any escape of the refrigerant gas and protect in combination with the MSR controllers and warning devices primarly persons, but also the plant. MSR Electronic products comply with current regulations.
MSR delivers sensors, controllers and accessories for cooling systems.
We have pointed out some features of the datasheets to give you a short overview.
MSR Sensors for NH3 Ammonia
| Sensor type | Measuring range | Signal output | Type | Datasheet |
| Infrared | 0-10000ppm 0-3.5 vol% | 0(4)-20mA 0(2)-10V RS485 | ADT-D3-1120 | |
| El-chem. | 0-300ppm 0-1000ppm | 0(4)-20mA 0(2)-10V RS485 | ADT-X3-1120/25 | |
| El-chem. | 0-300ppm 0-1000ppm | 4-20mA 2-10V | MA-5-1120 | |
| Semi-conductor | 0-300ppm | 0(4)-20mA 0(2)-10V RS485 | ADT-33-1120 | |
| Semi-conductor | 30-300ppm | 4-20mA 2-10V | MA-3-1120 | |
| Pellistor | 0-100%LEL | 0(4)-20mA 0(2)-10V RS485 | ADT-23-3408 | |
| Pellistor | 0-100%LEL | 4-20mA 2-10V | MA-2-1120 | |
| El-chem. CESI / ATEX | 0-200ppm 0-1000ppm | 4-20mA RS485 | XT-21-1125 | |
| Pellistor CESI / ATEX | 0-100% UEG | 4-20mA RS485 | XT-21-3408 |
MSR Sensor for C2H4 Ethylene
| Sensor type | Measuring range | Signal output | Type | Datasheet |
| Pellistor | 0-100%LEL | 0(4)-20mA 0(2)-10V RS485 | ADT-23-3410 | |
| Pellistor CESI / ATEX | 0-100%LEL | 4-20mA RS485 | XT-21-3410P | |
| Infrared CESI / ATEX | 0-100%LEL | 4-20mA RS485 | XTA1-3410I | |
| Semi-conductor | 20-2000ppm | 4-20mA | MA-3-2089 | |
| Infrared | 0-2000ppm | 0(4)-20mA 0(2)-10V RS485 | ADT-D3-1189 | |
| El-chem. | 0-10ppm | 0(4)-20mA 0(2)-10V RS485 | ADT-53-1189 | |
| Semi-conductor | 20-2000ppm | 0(4)-20mA 0(2)-10V RS485 | ADT-43-1189 | |
| El-chem. CESI / ATEX | 0-200ppm | 4-20mA RS485 | XT-21-1190 |
The MSR Single Point Controllers for refrigerants
| Gas | Analog inputs | Digital outputs | Type | Datasheet |
| NH3 | 2 | 4 | SPC-23-1120 | |
| NH3 | 2 | 4 | SPC-33-1120 | |
| NH3 | 2 | 4 | SPC-D3-1120 | |
| Freon | 2 | 4 | SPC-43-20xx | |
| Freon | 2 | 4 | SPC-D3-20xx | |
| CO2 | 2 | 4 | SPC-D3-1164 | |
| C2H4 | 2 | 4 | SPC-23-3410 | |
| C2H4 | 2 | 4 | SPC-43-1189 | |
| C2H4 | 2 | 4 | SPC-53-1189 | |
| C2H4 | 2 | 4 | SPC-D3-1189 |
Please click on PDF to download the corresponding file.